Reduksi Harmonisa Pada Saluran Distribusi Tenaga Listrik Dengan Filter Daya Aktif
Abstract
The large use of power converters in distribution lines causes poor power quality such as high produces harmonics in an electric power system that arises due to the operation of non-linear electrical equipment. The presence of harmonics in the power system distribution results in a very large loss in the system. In this paper had been done a simulation of power quality improvement through harmonic reduction using parallel active power filter. Active power filters work with control techniques based on the concept of instantaneous power to determine the amount of compensation currents that must be generated by the power compensator power circuit. The compensating current references generated by the control circuit are used by the hysteresis type controller to provide harmonic compensation arising. From the result of simulation using Simulink MATLAB, the harmonic value (THD) decrease caused by the 3 phase rectifier load on a distribution network which is used as case example. The harmonic value before compensated on the network is 27.85% at each phase, while after computing the harmonic value of the network decreases to 1,43% in R phase, 1,49% in S phase, and 1,34% in T phase.
Downloads
References
[2] Arrillaga, J. and Watson, N., “Power Systems Harmonics”, 2nd ed., Wiley, New York, 2003
[3] H. Akagi, E.H. Watanabe, M. Aredes, “Instantaneous Power Theory And Applications To Power Conditioning”, John Wiley & Sons. 2007
[4] Pirog S., Shklyarskiy Ya.E., Skamyin A.N. “Non-linear Electrical Load Location Identification”. Journal of Mining Institute. 2019. Vol. 237, p. 317-321. DOI:10.31897/PMI.2019.3.317
[5] Putra, A. W. “Analisis Penggunaan Filter Harmonic Untuk Mengurangi Efek Harmonisa Pada Sistem Kelistrikan Kapal Isap Produksi”. energi 2023, 14, 160-168: https://doi.org/10.33322/energi.v14i2.1589
[6] De La Rosa, FC. “Harmonics And Power Systems” Taylor & Francis Group, LLC, New York, 2006
[7] Dao, T. and Phung, B.T, Effects of voltage harmonic on losses and temperature rise in distribution transformers. IET Gener. Transm. Distrib. 2018, 12: 347-354. https://doi.org/10.1049/iet-gtd.2017.0498
[8] E. H. Watanabe, M. Aredes, J. L. Afonso, J. G. Pinto, L. F. C. Monteiro and H. Akagi, "Instantaneous p–q power theory for control of compensators in micro-grids," 2010 International School on Nonsinusoidal Currents and Compensation, Lagow, Poland, 2010, pp. 17-26, doi: 10.1109/ISNCC.2010.5524475.
[9] Imam, A. A.; Sreerama Kumar, R.; Al-Turki, Y.A. Modeling and Simulation of a PI Controlled Shunt Active Power Filter for Power Quality Enhancement Based on P-Q Theory. Electronics 2020, 9, 637. https://doi.org/10.3390/electronics9040637
[10] M. Zagirnyak, M. Maliakova and A. Kalinov, "Analysis of operation of power components compensation systems at harmonic distortions of mains supply voltage," Intl Symposium on Advanced Electromechanical Motion Systems (ELECTROMOTION), Side, Turkey, 2015, pp. 355-362, https://doi.org/10.1109/OPTIM.2015.7426958.
[11] Cahyono, M. R. A. (2018). “Analisa Pemanfaatan Harmonisa Sebagai Sumber Energi Alternatif dengan Filter Pasif”. JNTE 7(3), 161–168. https://doi.org/10.25077/jnte.v7n3.595.2018
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.